Site Map Home
HomeApplicationsApplicationsResourcesProject ProfilesClientsSustainabilityContact Us

Products


All of the below files are PDF documents. If you need to install Adobe Reader, click here.

Staycell® 245-2.0 Spray Foam Insulation

Staycell® 245-2.0 is a two-part, spray-applied, closed-cell polyurethane foam insulation material used to insulate structural steel, ceilings, roof decks, walls, tanks and as an air barrier in building envelope assemblies.

PDF Downloads    
Technical Data Sheet - Staycell® 245-2.0 Application Guide - Staycell® 245-2.0
MSDS-Staycell® 245-2.0 - A Component MSDS-Staycell® 245-2.0 - B Component




Staycell ONE STEP® 255 Spray Foam Insulation (MONOLITHIC System)

Staycell ONE STEP® 255 is a two-part, spray-applied, closed-cell polyurethane foam insulation material used to insulate structural steel, ceilings, roof decks, walls and tanks and as an air barrier in building envelope assemblies.

This new, revolutionary product is used in occupied/unoccupied spaces and can be left exposed without ignition/thermal barriers or any other type of fire protective surface.

PDF Downloads    
Technical Data Sheet - Staycell ONE STEP® 255
Guide Specification - Staycell® MONOLITHIC System (WORD) Guide Specification - Staycell® MONOLITHIC System (PDF)
Staycell ONE STEP® Brochure
MSDS - Staycell ONE STEP® 255 Component A MSDS - Staycell ONE STEP® 255 Component B Application Guide - Staycell ONE STEP® 255



Staycell® HYBRID Spray Foam Insulation System

The Staycell® HYBRID Insulation System is comprised of two separate layers of closed-cell spray polyurethane foam and is used to insulate ceilings and underside of roofs.

The HYBRID System can be installed in occupied and unoccupied spaces and is code-compliant without 15-minute thermal barriers, ignition barriers or other types of fire protective surfaces in most applications. 

Base layer: Staycell® 265 Spray Foam Insulation

Top layer: Staycell ONE STEP® 255 Spray Foam Insulation

PDF Downloads    
Technical Data Sheet - Staycell® HYBRID System Guide Specification-Staycell® HYBRID System (WORD) Guide Specification-Staycell® HYBRID System (PDF)



Staycell® 265 Spray Foam Insulation

Staycell® 265 is a two-part, spray-applied, closed-cell polyurethane foam insulation material used to insulate structural steel, ceilings, roof decks, walls, tanks and as an air barrier in building envelope assemblies.Staycell® 265 serves as the base layer to the Staycell® HYBRID System.

PDF Downloads  
Technical Data Sheet - Staycell® 265 MSDS-Staycell® 265 - A Component
Application Guide - Staycell® 265 MSDS-Staycell® 265 - B Component



Stayflex® 2505 Thermal Barrier Coating

Stayflex® 2505 is a chemical resistant, durable, thermal barrier coating for spray polyurethane foam (SPF) applications. Stayflex® 2505 is formulated from the same types of resins used in high performance products such as fiberglass tanks, chemical piping and grating

PDF Downloads    
Technical Data Sheet - Stayflex® 2505
Guide Specification - Stayflex® Corrosion Control & Thermal Insulation System (WORD) Guide Specification - Stayflex® Corrosion Control & Thermal Insulation System (PDF)
Stayflex® Corrosion Control System Brochure MSDS - Stayflex® 2505
Application Guide - Stayflex® 2505 & Staycoat 2510




Staycoat® 2510 Gelcoat Topcoat

Staycoat® 2510 is a thin-build USDA/FDA compliant polymer topcoat applied over Stayflex® 2505 when enhanced washability, chemical resistance or gloss is required.

PDF Downloads    
Technical Data Sheet - Staycoat® 2510 MSDS - Staycoat® 2510 Application Guide - Stayflex® 2505 Thermal Barrier Coating & Staycoat® 2510



HP-90 Catalyst

HP-90 is an initiator (catalyst) used for curing the Stayflex® 2505 and Staycoat® 2510 coatings.

PDF Downloads    
MSDS HP-90 Catalyst